TE Connectivity / Schaffner Power Line Filters

Results: 1 829
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Filter Type Voltage Rating Current Rating Mounting Style Termination Style Leakage Current Series Packaging Operating Frequency
TE Connectivity / Schaffner Power Line Filters 250Vac 1A 20mH Faston EMI Filter Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Single-Stage Filter 250 VAC 1 A Chassis Mount Faston 4.91 mA FN2030 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 250Vac 12A 4mH Faston EMI Filter Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Single-Stage Filter 250 VAC 12 A Chassis Mount Faston 4.91 mA FN2030 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 250Vac 8A 8mH Faston EMI Filter Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Single-Stage Filter 250 VAC 8 A Chassis Mount Faston 4.91 mA FN2030 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 1A Fast-on SRGE PLSE PROTECTION Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Single-Stage Filter 250 VAC 1 A Chassis Mount Faston 310 mA FN2030 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 12A Fast-on SRGE PLSE PROTECTION Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Single-Stage Filter 250 VAC 12 A Faston 1.41 mA FN2030 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 16A Fast-on SRGE PLSE PROTECTION Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase EMI General Purpose 250 VAC 16 A Chassis Mount Faston 1.41 mA FN2030 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters FN2030Z-20-07 Non-Stocked Lead-Time 16 Weeks
Min.: 20
Mult.: 20

1-Phase EMI General Purpose 250 VAC, 250 VDC 20 A Chassis Mount Wire 790 uA FN2030 400 Hz
TE Connectivity / Schaffner Power Line Filters 4A Fast-on SRGE PLSE PROTECTION Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Single-Stage Filter 250 VAC 4 A Chassis Mount Faston 470 uA FN2030 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 8A Fast-on SRGE PLSE PROTECTION Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Single-Stage Filter 250 VAC 8 A Faston 660 uA FN2030 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters MULTI-STAGE 12A FILTER 1-PHASE Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 12 A Chassis Mount Wire 660 uA FN2060 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters MULTI-STAGE 16A FILTER 1-PHASE Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 16 A Chassis Mount Wire 660 uA FN2060 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 30A SAFETY M4 SCREW GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 30 A Chassis Mount Screw 70 mA FN2060 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 1A MEDICAL FASTON GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Two-Stage Medical Filter 250 VAC 1 A Chassis Mount Faston 0 A FN2060 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 1A 250VAC 50/60Hz Wire Leads Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Two-Stage Filter 250 VAC 1 A Chassis Mount Wire 660 uA FN2070 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 12A 250VAC 50/60Hz Wire Leads Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 12 A Chassis Mount Wire 660 uA FN2070 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 3A 250VAC 50/60Hz Wire Leads Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 3 A Chassis Mount Wire 660 uA FN2070 Tray 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 10A SAFETY FASTON GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 10 A Chassis Mount Faston 70 mA FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 3A SAFETY FASTON GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 3 A Chassis Mount Faston 70 mA FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 6A SAFETY WIRE LEADS General Purpose Fltr Non-Stocked Lead-Time 16 Weeks
Min.: 20
Mult.: 20

1-Phase Two-Stage Filter 250 VAC 6 A Chassis Mount Wire 70 mA FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters FN2070B-1-06 Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 1 A Chassis Mount Faston 0 A FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 10A MEDICAL FASTON GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 10 A Chassis Mount Faston 0 A FN2070 Bulk 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 16A MEDICAL FASTON GENERAL PURPOSE FLTR 7In Stock
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 16 A Chassis Mount Faston 0 A FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters MEDICAL GRADE FILTER Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 3 A Chassis Mount Faston 0 A FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 1A 22mH 250VAC AC/DC EMI Filter Non-Stocked Lead-Time 16 Weeks
Min.: 50
Mult.: 50

1-Phase Two-Stage Filter 250 VAC 1 A Chassis Mount Faston 3.69 mA FN2070 0 Hz to 400 Hz
TE Connectivity / Schaffner Power Line Filters 12A FASTON GENERAL PURPOSE FLTR Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

1-Phase Two-Stage Filter 250 VAC 12 A Chassis Mount Faston 3.69 mA FN2070 0 Hz to 400 Hz